The Scientific Working Group on Imaging Technology was convened by the Federal Bureau of Investigation in 1997 to provide guidance to law enforcement agencies and others in the criminal justice system regarding the best practices for photography, videography, and video and image analysis. This group was terminated in 2015. == History == As technology has advanced through the years, law enforcement has needed to stay abreast of emerging technological advances and use these in the investigation of crime. A factor that is considered when new technology is used in these investigations is the determination of whether the use of that new technology will be admissible in court. The judicial system in the United States currently has two standards used in the determination of admissibility of testimony regarding scientific evidence; the Daubert Standard and the Frye Standard. These standards guide the courts in the admissibility of testimony derived from the use of new technologies and scientific techniques. The Federal Bureau of Investigation (FBI), seeking to address possible admissibility issues with such testimony, established Scientific Working Groups starting with the Scientific Working Group on DNA Analysis and Methods (SWGDAM) in 1988. The goal of these groups is to open lines of communication between law enforcement agencies and forensic laboratories around the world while providing guidance on the use of new and innovative technologies and techniques. This guidance can lead to admissibility of evidence and/or testimony, provided proper methods in the collection of evidence and its analysis are employed. In 2009, the National Academy of Sciences released a report entitled, "Strengthening Forensic Science in the United States: A Path Forward." This report addresses many topics including challenges and disparities facing the forensic science community, standardization, certification of practitioners and accreditation of their respective entities, problems related to the interpretation of forensic evidence, the need for research, and the admission of forensic science evidence in litigation. This report mentions the Scientific Working Groups and their role in forensic science. The history of imaging technology (photography) can be said to extend back to the times of Chinese philosopher Mo-Ti (470-390 B.C.) who described the principles behind the precursor to the camera obscura. Since that time, advances in imaging technology include the discovery of chemical photographic processes in the 19th century and the use of electronic imaging technology that includes analog video cameras and digital video and still cameras. By the mid 1990s, it was apparent that technologically advanced camera systems such as these were being adopted for use in the criminal justice system. This led the FBI to convene a meeting of individuals working in the field of forensic imaging from federal, state, local, and foreign law enforcement, and the U.S. military, during the summer of 1997. As a result of this meeting, the Technical Working Group on Imaging Technology was formed from a core group of the meeting’s participants. This group later became the Scientific Working Group on Imaging Technology (SWGIT). Prior to the inception of SWGIT, some law enforcement agencies began adopting digital imaging technology. Due to the lack of guidelines or standards, some of these agencies attempted to replace all their film cameras with substandard digital cameras, only to find that the equipment they had purchased was not capable of accomplishing the mission for which they were intended. At that time only low resolution digital cameras were deemed affordable by some law enforcement agencies. Some of these agencies were forced to rethink their photography procedures and reverted to the use of film cameras or replaced their low-resolution digital cameras with higher quality, more expensive equipment. Also lacking at this early stage was guidance on how to store and archive digital image files. When SWGIT was formed, it was tasked with providing guidance to law enforcement and others in the criminal justice system by releasing documents that describe the best practices and guidelines for the use of imaging technology, to include these concerns and many others. This group was terminated in 2015. == SWGIT Function == During its existence, SWGIT provided information on the appropriate use of various imaging technologies including both established and new. This was accomplished through the release of documents such as the SWGIT Best Practices documents. As changes in technology occurred, these documents were updated. Over the course of its existence, SWGIT collaborated with other Scientific Working Groups to address imaging concerns within their respective disciplines. SWGIT published over 20 documents that dealt specifically with imaging technology. SWGIT also co-published documents with the Scientific Working Group on Digital Evidence (SWGDE) that had a component or components dealing with imaging technology. SWGIT also provided imaging technology guidance and input for documents from the Scientific Working Group on Friction Ridge Analysis, Study and Technology (SWGFAST), the Scientific Working Group for Forensic Document Examination (SWGDOC), and the Scientific Working Group on Shoeprint and Tire Tread Evidence (SWGTREAD). SWGIT assisted the American Society of Crime Lab Directors/Laboratory Accreditation Board (ASCLD/LAB) in the writing of definitions and standards for the accreditation of Digital and Multimedia Evidence sections of crime laboratories. In addition to releasing documents, SWGIT members disseminated best practices for law enforcement professionals where imaging technology was concerned. This was carried out by attending and lecturing at meetings and conferences of various forensic organizations that included: The American Academy of Forensic Sciences (AAFS) The International Association for Identification (IAI) The Law Enforcement and Emergency Services Video Association (LEVA) The American Society of Crime Lab Directors (ASCLD) The SWGIT membership consisted of approximately fifty scientists, photographers, instructors, and managers from more than two dozen federal, state, and local law enforcement agencies, as well as from the academic and research communities. The membership elected its officers from within. SWGIT was composed of the Executive Committee, four standing subcommittees, and ad hoc subcommittees appointed on an as-needed basis. The standing subcommittees were: Image Analysis, Forensic Photography, Video, and Outreach. This group was terminated in 2015. == Legal Proceedings == The following court cases have conducted Daubert v. Merrell Dow Pharm., Inc., 509 U.S. 579 (1993) hearings in which SWGIT best practice documents have been cited as accepted protocol, methodology, and as generally accepted techniques in the forensic community: U. S. v. Rudy Frabizio, U.S. District Court, Boston, MA, 2008 (Image Authentication) U.S. v. Nobumochi Furukawa, U.S. District Court, Minnesota, 2007 (Video Authentication) U.S. v. John Stroman, U.S. District Court, South Carolina, 2007 (Facial Comparison Analysis) State of Texas v. Daniel Day, Tarrant County Texas, 2005 (Camera Identification to Images) U.S. v. Marc Watzman, U.S. District Court, Northern Illinois, 2004 (Video Authentication) U.S. v. McKreith, U.S. District Court, Fort Lauderdale, FL, 2002 (Photo comparison of shirt) == Termination == This group was unfunded by the FBI in 2015.
Video renderer
A video renderer is software that processes a video file and sends it sequentially to the video display controller card for display on a computer screen. An example of a video renderer, is the VMR-7 that was used by Microsoft's DirectShow. An example of a UNIX video renderer is the one container within GStreamer. Commonly used video renderers are: Enhanced Video Renderer VMR9 Renderless Haali's Video Renderer Madvr Video Renderer JRVR, a part of JRiver Media Center
Image registration
Image registration is the process of transforming different sets of data into one coordinate system. Data may be multiple photographs, data from different sensors, times, depths, or viewpoints. It is used in computer vision, medical imaging, military automatic target recognition, and compiling and analyzing images and data from satellites. Registration is necessary in order to be able to compare or integrate the data obtained from these different measurements. == Algorithm classification == === Intensity-based vs feature-based === Image registration or image alignment algorithms can be classified into intensity-based and feature-based. One of the images is referred to as the target, fixed or sensed image and the others are referred to as the moving or source images. Image registration involves spatially transforming the source/moving image(s) to align with the target image. The reference frame in the target image is stationary, while the other datasets are transformed to match to the target. Intensity-based methods compare intensity patterns in images via correlation metrics, while feature-based methods find correspondence between image features such as points, lines, and contours. Intensity-based methods register entire images or sub-images. If sub-images are registered, centers of corresponding sub images are treated as corresponding feature points. Feature-based methods establish a correspondence between a number of especially distinct points in images. Knowing the correspondence between a number of points in images, a geometrical transformation is then determined to map the target image to the reference images, thereby establishing point-by-point correspondence between the reference and target images. Methods combining intensity-based and feature-based information have also been developed. === Transformation models === Image registration algorithms can also be classified according to the transformation models they use to relate the target image space to the reference image space. The first broad category of transformation models includes affine transformations, which include rotation, scaling, translation and shearing. Affine transformations are global in nature, thus, they cannot model local geometric differences between images. The second category of transformations allow 'elastic' or 'nonrigid' transformations. These transformations are capable of locally warping the target image to align with the reference image. Nonrigid transformations include radial basis functions (thin-plate or surface splines, multiquadrics, and compactly-supported transformations), physical continuum models (viscous fluids), and large deformation models (diffeomorphisms). Transformations are commonly described by a parametrization, where the model dictates the number of parameters. For instance, the translation of a full image can be described by a translation vector parameter. These models are called parametric models. Non-parametric models on the other hand, do not follow any parameterization, allowing each image element to be displaced arbitrarily. There are a number of programs that implement both estimation and application of a warp-field. It is a part of the SPM and AIR programs. === Transformations of coordinates via the law of function composition rather than addition === Alternatively, many advanced methods for spatial normalization are building on structure preserving transformations homeomorphisms and diffeomorphisms since they carry smooth submanifolds smoothly during transformation. Diffeomorphisms are generated in the modern field of Computational Anatomy based on flows since diffeomorphisms are not additive although they form a group, but a group under the law of function composition. For this reason, flows which generalize the ideas of additive groups allow for generating large deformations that preserve topology, providing 1-1 and onto transformations. Computational methods for generating such transformation are often called LDDMM which provide flows of diffeomorphisms as the main computational tool for connecting coordinate systems corresponding to the geodesic flows of Computational Anatomy. There are a number of programs which generate diffeomorphic transformations of coordinates via diffeomorphic mapping including MRI Studio and MRI Cloud.org === Spatial vs frequency domain methods === Spatial methods operate in the image domain, matching intensity patterns or features in images. Some of the feature matching algorithms are outgrowths of traditional techniques for performing manual image registration, in which an operator chooses corresponding control points (CP) in images. When the number of control points exceeds the minimum required to define the appropriate transformation model, iterative algorithms like RANSAC can be used to robustly estimate the parameters of a particular transformation type (e.g. affine) for registration of the images. Frequency-domain methods find the transformation parameters for registration of the images while working in the transform domain. Such methods work for simple transformations, such as translation, rotation, and scaling. Applying the phase correlation method to a pair of images produces a third image which contains a single peak. The location of this peak corresponds to the relative translation between the images. Unlike many spatial-domain algorithms, the phase correlation method is resilient to noise, occlusions, and other defects typical of medical or satellite images. Additionally, the phase correlation uses the fast Fourier transform to compute the cross-correlation between the two images, generally resulting in large performance gains. The method can be extended to determine rotation and scaling differences between two images by first converting the images to log-polar coordinates. Due to properties of the Fourier transform, the rotation and scaling parameters can be determined in a manner invariant to translation. === Single- vs multi-modality methods === Another classification can be made between single-modality and multi-modality methods. Single-modality methods tend to register images in the same modality acquired by the same scanner/sensor type, while multi-modality registration methods tended to register images acquired by different scanner/sensor types. Multi-modality registration methods are often used in medical imaging as images of a subject are frequently obtained from different scanners. Examples include registration of brain CT/MRI images or whole body PET/CT images for tumor localization, registration of contrast-enhanced CT images against non-contrast-enhanced CT images for segmentation of specific parts of the anatomy, and registration of ultrasound and CT images for prostate localization in radiotherapy. === Automatic vs interactive methods === Registration methods may be classified based on the level of automation they provide. Manual, interactive, semi-automatic, and automatic methods have been developed. Manual methods provide tools to align the images manually. Interactive methods reduce user bias by performing certain key operations automatically while still relying on the user to guide the registration. Semi-automatic methods perform more of the registration steps automatically but depend on the user to verify the correctness of a registration. Automatic methods do not allow any user interaction and perform all registration steps automatically. === Similarity measures for image registration === Image similarities are broadly used in medical imaging. An image similarity measure quantifies the degree of similarity between intensity patterns in two images. The choice of an image similarity measure depends on the modality of the images to be registered. Common examples of image similarity measures include cross-correlation, mutual information, sum of squared intensity differences, and ratio image uniformity. Mutual information and normalized mutual information are the most popular image similarity measures for registration of multimodality images. Cross-correlation, sum of squared intensity differences and ratio image uniformity are commonly used for registration of images in the same modality. Many new features have been derived for cost functions based on matching methods via large deformations have emerged in the field Computational Anatomy including Measure matching which are pointsets or landmarks without correspondence, Curve matching and Surface matching via mathematical currents and varifolds. == Uncertainty == There is a level of uncertainty associated with registering images that have any spatio-temporal differences. A confident registration with a measure of uncertainty is critical for many change detection applications such as medical diagnostics. In remote sensing applications where a digital image pixel may represent several kilometers of spatial distance (such as NASA's LANDSAT imagery), an uncertain image registration can mean that a solution could b
Connected-component labeling
Connected-component labeling (CCL), connected-component analysis (CCA), blob extraction, region labeling, blob discovery, or region extraction is an algorithmic application of graph theory, where subsets of connected components are uniquely labeled based on a given heuristic. Connected-component labeling is not to be confused with segmentation. Connected-component labeling is used in computer vision to detect connected regions in binary digital images, although color images and data with higher dimensionality can also be processed. When integrated into an image recognition system or human-computer interaction interface, connected component labeling can operate on a variety of information. Blob extraction is generally performed on the resulting binary image from a thresholding step, but it can be applicable to gray-scale and color images as well. Blobs may be counted, filtered, and tracked. Blob extraction is related to but distinct from blob detection. == Overview == A graph, containing vertices and connecting edges, is constructed from relevant input data. The vertices contain information required by the comparison heuristic, while the edges indicate connected 'neighbors'. An algorithm traverses the graph, labeling the vertices based on the connectivity and relative values of their neighbors. Connectivity is determined by the medium; image graphs, for example, can be 4-connected neighborhood or 8-connected neighborhood. Following the labeling stage, the graph may be partitioned into subsets, after which the original information can be recovered and processed . == Definition == The usage of the term connected-component labeling (CCL) and its definition is quite consistent in the academic literature, whereas connected-component analysis (CCA) varies both in terminology and in its definition of the problem. Rosenfeld et al. define connected components labeling as the “[c]reation of a labeled image in which the positions associated with the same connected component of the binary input image have a unique label.” Shapiro et al. define CCL as an operator whose “input is a binary image and [...] output is a symbolic image in which the label assigned to each pixel is an integer uniquely identifying the connected component to which that pixel belongs.” There is no consensus on the definition of CCA in the academic literature. It is often used interchangeably with CCL. A more extensive definition is given by Shapiro et al.: “Connected component analysis consists of connected component labeling of the black pixels followed by property measurement of the component regions and decision making.” The definition for connected-component analysis presented here is more general, taking the thoughts expressed in into account. == Algorithms == The algorithms discussed can be generalised to arbitrary dimensions, albeit with increased time and space complexity. === One component at a time === This is a fast and very simple method to implement and understand. It is based on graph traversal methods in graph theory. In short, once the first pixel of a connected component is found, all the connected pixels of that connected component are labelled before going onto the next pixel in the image. This algorithm is part of Vincent and Soille's watershed segmentation algorithm, other implementations also exist. In order to do that a linked list is formed that will keep the indexes of the pixels that are connected to each other, steps (2) and (3) below. The method of defining the linked list specifies the use of a depth or a breadth first search. For this particular application, there is no difference which strategy to use. The simplest kind of a last in first out queue implemented as a singly linked list will result in a depth first search strategy. It is assumed that the input image is a binary image, with pixels being either background or foreground and that the connected components in the foreground pixels are desired. The algorithm steps can be written as: Start from the first pixel in the image. Set current label to 1. Go to (2). If this pixel is a foreground pixel and it is not already labelled, give it the current label and add it as the first element in a queue, then go to (3). If it is a background pixel or it was already labelled, then repeat (2) for the next pixel in the image. Pop out an element from the queue, and look at its neighbours (based on any type of connectivity). If a neighbour is a foreground pixel and is not already labelled, give it the current label and add it to the queue. Repeat (3) until there are no more elements in the queue. Go to (2) for the next pixel in the image and increment current label by 1. Note that the pixels are labelled before being put into the queue. The queue will only keep a pixel to check its neighbours and add them to the queue if necessary. This algorithm only needs to check the neighbours of each foreground pixel once and doesn't check the neighbours of background pixels. The pseudocode is: algorithm OneComponentAtATime(data) input : imageData[xDim][yDim] initialization : label = 0, labelArray[xDim][yDim] = 0, statusArray[xDim][yDim] = false, queue1, queue2; for i = 0 to xDim do for j = 0 to yDim do if imageData[i][j] has not been processed do if imageData[i][j] is a foreground pixel do check its four neighbors(north, south, east, west) : if neighbor is not processed do if neighbor is a foreground pixel do add it to queue1 else update its status to processed end if labelArray[i][j] = label (give label) statusArray[i][j] = true (update status) while queue1 is not empty do For each pixel in the queue do : check its four neighbors if neighbor is not processed do if neighbor is a foreground pixel do add it to queue2 else update its status to processed end if give it the current label update its status to processed remove the current element from queue1 copy queue2 into queue1 end While increase the label end if else update its status to processed end if end if end if end for end for === Two-pass === Relatively simple to implement and understand, the two-pass algorithm, (also known as the Hoshen–Kopelman algorithm) iterates through 2-dimensional binary data. The algorithm makes two passes over the image: the first pass to assign temporary labels and record equivalences, and the second pass to replace each temporary label by the smallest label of its equivalence class. The input data can be modified in situ (which carries the risk of data corruption), or labeling information can be maintained in an additional data structure. Connectivity checks are carried out by checking neighbor pixels' labels (neighbor elements whose labels are not assigned yet are ignored), or say, the north-east, the north, the north-west and the west of the current pixel (assuming 8-connectivity). 4-connectivity uses only north and west neighbors of the current pixel. The following conditions are checked to determine the value of the label to be assigned to the current pixel (4-connectivity is assumed) Conditions to check: Does the pixel to the left (west) have the same value as the current pixel? Yes – We are in the same region. Assign the same label to the current pixel No – Check next condition Do both pixels to the north and west of the current pixel have the same value as the current pixel but not the same label? Yes – We know that the north and west pixels belong to the same region and must be merged. Assign the current pixel the minimum of the north and west labels, and record their equivalence relationship No – Check next condition Does the pixel to the left (west) have a different value and the one to the north the same value as the current pixel? Yes – Assign the label of the north pixel to the current pixel No – Check next condition Do the pixel's north and west neighbors have different pixel values than current pixel? Yes – Create a new label id and assign it to the current pixel The algorithm continues this way, and creates new region labels whenever necessary. The key to a fast algorithm, however, is how this merging is done. This algorithm uses the union-find data structure which provides excellent performance for keeping track of equivalence relationships. Union-find essentially stores labels which correspond to the same blob in a disjoint-set data structure, making it easy to remember the equivalence of two labels by the use of an interface method E.g.: findSet(l). findSet(l) returns the minimum label value that is equivalent to the function argument 'l'. Once the initial labeling and equivalence recording is completed, the second pass merely replaces each pixel label with its equivalent disjoint-set representative element. A faster-scanning algorithm for connected-region extraction is presented below. On the first pass: Iterate through each element of the data by column, then by row (Raster Scanning) If the element is not the background Get the neighboring elements of the current element If there are no neighbors, uniquely
Version space learning
Version space learning is a logical approach to machine learning, specifically binary classification. Version space learning algorithms search a predefined space of hypotheses, viewed as a set of logical sentences. Formally, the hypothesis space is a disjunction H 1 ∨ H 2 ∨ . . . ∨ H n {\displaystyle H_{1}\lor H_{2}\lor ...\lor H_{n}} (i.e., one or more of hypotheses 1 through n are true). A version space learning algorithm is presented with examples, which it will use to restrict its hypothesis space; for each example x, the hypotheses that are inconsistent with x are removed from the space. This iterative refining of the hypothesis space is called the candidate elimination algorithm, the hypothesis space maintained inside the algorithm, its version space. == The version space algorithm == In settings where there is a generality-ordering on hypotheses, it is possible to represent the version space by two sets of hypotheses: (1) the most specific consistent hypotheses, and (2) the most general consistent hypotheses, where "consistent" indicates agreement with observed data. The most specific hypotheses (i.e., the specific boundary SB) cover the observed positive training examples, and as little of the remaining feature space as possible. These hypotheses, if reduced any further, exclude a positive training example, and hence become inconsistent. These minimal hypotheses essentially constitute a (pessimistic) claim that the true concept is defined just by the positive data already observed: Thus, if a novel (never-before-seen) data point is observed, it should be assumed to be negative. (I.e., if data has not previously been ruled in, then it's ruled out.) The most general hypotheses (i.e., the general boundary GB) cover the observed positive training examples, but also cover as much of the remaining feature space without including any negative training examples. These, if enlarged any further, include a negative training example, and hence become inconsistent. These maximal hypotheses essentially constitute a (optimistic) claim that the true concept is defined just by the negative data already observed: Thus, if a novel (never-before-seen) data point is observed, it should be assumed to be positive. (I.e., if data has not previously been ruled out, then it's ruled in.) Thus, during learning, the version space (which itself is a set – possibly infinite – containing all consistent hypotheses) can be represented by just its lower and upper bounds (maximally general and maximally specific hypothesis sets), and learning operations can be performed just on these representative sets. After learning, classification can be performed on unseen examples by testing the hypothesis learned by the algorithm. If the example is consistent with multiple hypotheses, a majority vote rule can be applied. == Historical background == The notion of version spaces was introduced by Mitchell in the early 1980s as a framework for understanding the basic problem of supervised learning within the context of solution search. Although the basic "candidate elimination" search method that accompanies the version space framework is not a popular learning algorithm, there are some practical implementations that have been developed (e.g., Sverdlik & Reynolds 1992, Hong & Tsang 1997, Dubois & Quafafou 2002). A major drawback of version space learning is its inability to deal with noise: any pair of inconsistent examples can cause the version space to collapse, i.e., become empty, so that classification becomes impossible. One solution of this problem is proposed by Dubois and Quafafou that proposed the Rough Version Space, where rough sets based approximations are used to learn certain and possible hypothesis in the presence of inconsistent data.
NHS COVID-19
NHS COVID-19 was a voluntary contact tracing app for monitoring the spread of the COVID-19 pandemic in England and Wales, in use from 24 September 2020 until 27 April 2023. It was available for Android and iOS smartphones, and could be used by anyone aged 16 or over. Two versions of the app were created. The first was commissioned by NHSX and developed by the Pivotal division of American software company VMware. A pilot deployment began in May 2020, but on 18 June development of the app was abandoned in favour of a second design using the Apple/Google Exposure Notification system. Scotland and Northern Ireland had separate contact tracing apps. A 2023 study estimated that in its first year of use, the app's contact tracing function prevented an estimated 1 million cases, and 9,600 deaths. == Description == The app allowed users to: See the alert level of their local authority area (in Wales) or information about restrictions (in England); to enable this, the user must enter the first half of their postcode "Check in" at places displaying an NHS QR code poster (no longer required by legislation after 26 January 2022, removed from the app the next month) Be notified when they have been in close contact with someone who has tested positive for the virus Be notified when local health protection teams determine that people with the virus had attended a business or other venue around the same time as the user Check their symptoms, and book a coronavirus test if necessary If asked to self-isolate, receive information and a daily "countdown". At first, "close contact" was defined as being within 2 metres for 15 minutes, or within 4 metres for a longer time. These time durations were reduced from 29 October 2020, to as little as three minutes when the other person is at their most infectious, i.e. soon after they begin showing symptoms. === Implementation === The Android app was coded in Kotlin, and the iOS app in Swift. The backend used Java and is deployed to Amazon Web Services using Terraform. The code of the app and back-end is open-source and available on GitHub. == Context == The app was part of the UK's test and trace programme which was chaired by Dido Harding; from 12 May 2020 Tom Riordan, chief executive of Leeds City Council, led the tracing effort. == First phase and cancellation == === Description === In March 2020, NHSX commissioned a contact tracing app to monitor the spread in the United Kingdom of the coronavirus disease 2019 (COVID-19) in the 2020 pandemic, developed by the Pivotal division of American software company VMware. The app used a centralised approach, in contrast to the Google / Apple contact tracing project. NHSX consulted ethicists and GCHQ's National Cyber Security Centre (NCSC) about the privacy aspects. The app recorded the make and model of the phone and asked the user for their postcode area. It generated a unique installation identification number and also a daily identification number. It then used Bluetooth Low Energy (BLE) to record the daily identification number of other users nearby. If a user was unwell, they could tell the app about symptoms which are characteristic of COVID-19, such as a fever and cough. These details were then passed to a central NHS server. This would assess the information and notify other users that have been in contact, giving them appropriate advice such as physical distancing. The NHS would also arrange for a swab test of the unwell user and the outcome would determine further notifications to contacts: if the test confirmed infection with COVID-19, the contacts would be asked to isolate. By June 2020, £11.8 million had been spent on the app; in 2020–21, £35 million was spent on the app. === Deployment === The first public trial of the app began on the Isle of Wight on 5 May 2020 and by 11 May it had been downloaded 55,000 times. When the first national contact tracing schemes were launched – Test, Trace, Protect in Wales on 13 May, then on 28 May NHS Test and Trace in England, and Test and Protect in Scotland – the app was not ready to be included. Replying to a question at the government's daily briefing on 8 June, Hancock was unable to give a date for rollout of the app in England, saying it would be brought in "when it's right to do so". On 17 June, Lord Bethell, junior minister for Innovation at the Department of Health and Social Care, said "we're seeking to get something going before the winter ... it isn't a priority for us at the moment". On 18 June, Health Secretary Matt Hancock announced development would switch to the Apple/Google system after admitting that Apple's restrictions on usage of Bluetooth prevented the app from working effectively. At the same press briefing Dido Harding, leader of the UK's test and trace programme, said "What we've done in really rigorously testing both our own Covid-19 app and the Google-Apple version is demonstrate that none of them are working sufficiently well enough to be actually reliable to determine whether any of us should self-isolate for two weeks [and] that's true across the world". === Concerns === The first, ultimately rejected, version of the app was subject to privacy concerns, the government backtracking on initial statements that the data collected from the app would not be shared outside the NHS. Matthew Gould, CEO of NHSX, the government department responsible for the app, said the data would be accessible to other organisations, but did not disclose which. Data collected would not necessarily be anonymised and would be held in a centralised repository. Over 150 of the UK's security and privacy experts warned the app's data could be used by 'a bad actor (state, private sector, or hacker)' to spy on citizens. Fears were discussed by the House of Commons' Human Rights Select Committee about plans for the app to record user location data. Parliament's Joint Committee on Human Rights said this version of the app should not be released without proper privacy protections. The second version of the app, released nationwide, addressed these concerns by employing a decentralised framework, the Apple/Google Exposure Notification system. Under this system, users remain pseudonymous: a person diagnosed with COVID-19 does not know which people are informed about an encounter, and contacted persons do not receive any information about the person diagnosed with COVID-19. The functionality of the app was also questioned in late April and early May 2020, as the software's use of Bluetooth required the app to be constantly running, meaning users could not use other apps or lock their device if the app was to function properly. The developers of the app were said to have found a way of working around this restriction. === Related contracts === Faculty – a company linked to Cambridge Analytica – provided research and modelling to NHSX in support of the response to the pandemic. Palantir, also linked to Cambridge Analytica, provided their data management platform. These contracts began in February and March respectively. == Second phase == As outlined on cancellation of the first app on 18 June 2020, the Department of Health and Social Care published on 30 July a brief description of the "next phase" app. Users would be able to scan a QR code at venues they visit, and later be notified if they had visited a place which was the source of a number of infections; the app would also assist with identifying symptoms and ordering a test. By using the Exposure Notification system from Apple and Google, personal data would be decentralised. Zuhlke Engineering Ltd, the UK branch of Swiss-based Zühlke Group, used 70 staff to complete the development of the app in 12 weeks. Zuhlke Engineering was awarded "Development Team of the Year" title at UK IT Industry awards in November 2021 for development of NHS COVID-19 application. === Timeline === Testing of the app by NHS volunteer responders, and selected residents of the Isle of Wight and the London Borough of Newham, began around 13 August. The app was made available to the public (aged 16 or over) in England and Wales on 24 September. An updated app released on 29 October, in part from collaboration with the Alan Turing Institute, improved the accuracy of measurements of the distance between the user's phone and other phones. At the same time, the duration threshold for determining exposure was reduced; this was expected to lead to an increase in the number of users told to self-isolate. An update to the app in April 2021, timed to coincide with easing of restrictions on hospitality businesses, was blocked by Apple and Google. It was intended that users who tested positive would be asked to share their history of visited venues, to assist in warning others, but this would have contravened assurances by Apple and Google that location data from devices would not be shared. === Statistics and effectiveness === The app was downloaded six million times on the first day it was generally availa
Vicuna LLM
Vicuna LLM is an omnibus large language model used in AI research. Its methodology is to enable the public at large to contrast and compare the accuracy of LLMs "in the wild" (an example of citizen science) and to vote on their output; a question-and-answer chat format is used. At the beginning of each round two LLM chatbots from a diverse pool of nine are presented randomly and anonymously, their identities only being revealed upon voting on their answers. The user has the option of either replaying ("regenerating") a round, or beginning an entirely fresh one with new LLMs. (The user also has the option of choosing which LLMs to do battle.) Based on Llama 2, it is an open source project, and it itself has become the subject of academic research in the burgeoning field. A non-commercial, public demo of the Vicuna-13b model is available to access using LMSYS.